PC PAUT Program - DSViewer
DSViewer reads all collected data and utilizes various functions for analysis and inspection.
It supports various features such as defect size measurement, defect location finding, and zooming for precise inspection.


Load DSVIEWER data file
DSViewer loads the collected data and displays it on the screen.
DEEPSOUND's data files are in DSV format. All collected data is saved as .dsv files.

Add Scan View
The viewer provides a menu for users to configure their desired scan views.
A total of 5 scans are supported: S/A/B/C/D. Click on the desired scan to apply it immediately.

Add Scan Image
Select the scan window you want to move and use the feature to place it in your desired location.

Menu View
The View menu has a function to display defect information on the screen.
These functions include Bar/Gate/Flip/Swap/Zoom Reset.

Reference/Measurement bar
Select and activate the desired bar from the View menu. The defect size can be measured with the cursor, and you can check more detailed data values in the information section.
When you enable display values, the position values of the bar are shown on the screen, and they disappear when deactivated.

Gate Menu View
You can select the gate to activate from the View menu. Once activated, the gate is applied to the A-scan image, allowing you to freely change the signal position, height, and area to inspect.
You can change the gate length and height using mouse controls, but you can also modify the length through the Gat/Range Control tool in the top menu.

Range Menu View
When View Range is activated, a controllable area is created under the ruler in B-scan/D-scan.
The color of the area represents the same axis as the ruler, allowing you to control the area to only display the target defects you want to inspect.

Zoom/Reset Control
Zoom in on the data image or reset it to its original size.
Hold Shift+Left Mouse button and drag to select the area you want to zoom into. The zoom/reset will only affect the selected screen/window.